Low voltage electrical cables

Reliability, the fruit of experience

The assurance of a response to every need

Quality is never an accident, it is always the result of a great effort

Low voltage electrical cables

Reliability, the fruit of experience

The assurance of a response to every need

Quality is never an accident, it is always the result of a great effort

Halogen free cable tubing 0,6 - 1KV

RZ1-K (AS) (1,5 a 6mm2 - 2 to 5 conductors) Cca, s1b, d1, a1

Manufacturing standards:
UNE 21123-4/2017
Standard 50575
Regulation CPR 305/2011

Description: Multicable tubing with electrolytic copper conductor with class 5 flexibility and green polyolefin sheath.

Applications: Distribution of low-voltage power in residential buildings and public premises where safe fire performance of the cable is required and reduced emission of smoke and toxic gases.

Characteristics:
> Conductor: flexible electrolytic copper (class 5).
> Polyolefin sheath and insulation.
> UNE-EN 50399 standard: 2012. Test under fire conditions.
> UNE-EN 60332-1-2 standard. Resistance to vertical flame propagation.
> UNE-EN 61034-2 standard. Low smoke emission.
> UNE-EN 60754-2 standard. Degree of acidity.
> Rated voltage: 06/1KV.
> Test voltage: 3500V.


Available colours:

Customisable printing

Dimensions:


Cross-section (mm²)

Insulation thickness (mm)

Sheath thickness (mm)

Approximate outer diameter (mm)
6G1,5 0,70 1,40 11,40
7G1,5 0,70 1,40 11,40
8G1,5 0,70 1,40 12,15
10G1,5 0,70 1,40 13,90
12G1,5 0,70 1,40 15,00
14G1,5 0,70 1,40 15,40
16G1,5 0,70 1,40 16,00
20G1,5 0,70 1,40 18,20
24G1,5 0,70 1,40 21,00
25G1,5 0,70 1,40 22,50
30G1,5 0,70 1,40 24,00
6G2,5 0,70 1,40 13,50
7G2,5 0,70 1,40 13,50
8G2,5 0,70 1,40 15,20

RZ1-K (AS) (1,5mm2 - 6 to 30 conductors) (2,5mm2 - 6 to 30 conductors) Cca, s1b, d1, a1

Manufacturing standards:
UNE 21123-4/2017
Standard 50575
Regulation CPR 305/2011

Description: Multicable tubing with electrolytic copper conductor with class 5 flexibility and green polyolefin sheath.

Applications: Distribution of low-voltage power in residential buildings and public premises where safe fire performance of the cable is required and reduced emission of smoke and toxic gases.

Characteristics:
> Conductor: flexible electrolytic copper (class 5).
> Polyolefin sheath and insulation.
> UNE-EN 50399 standard: 2012. Test under fire conditions.
> UNE-EN 60332-1-2 standard. Resistance to vertical flame propagation.
> UNE-EN 61034-2 standard. Low smoke emission.
> UNE-EN 60754-2 standard. Degree of acidity.
> Rated voltage: 06/1KV.
> Test voltage: 3500V.


Available colours: Y/G + Numbering

Customisable printing

Dimensions:


Cross-section (mm²)

Insulation thickness (mm)

Sheath thickness (mm)

Approximate outer diameter (mm)
6G1,5 0,70 1,40 11,40
7G1,5 0,70 1,40 11,40
8G1,5 0,70 1,40 12,15
10G1,5 0,70 1,40 13,90
12G1,5 0,70 1,40 15,00
14G1,5 0,70 1,40 15,40
16G1,5 0,70 1,40 16,00
20G1,5 0,70 1,40 18,20
24G1,5 0,70 1,40 21,00
25G1,5 0,70 1,40 22,50
30G1,5 0,70 1,40 24,00
6G2,5 0,70 1,40 13,50
7G2,5 0,70 1,40 13,50
8G2,5 0,70 1,40 15,20
10G2,5 0,70 1,40 16,40
12G2,5 0,70 1,40 17,00
14G2,5 0,70 1,40 18,40
16G2,5 0,70 1,40 19,50
20G2,5 0,70 1,40 22,00
24G2,5 0,70 1,40 24,50
25G2,5 0,70 1,40 25,00
30G2,5 0,70 1,40 28,00

Contact us

* I have read and accept the privacy policy